{"id":2951,"date":"2026-08-19T17:08:20","date_gmt":"2026-08-19T08:08:20","guid":{"rendered":"https:\/\/gene-academy.com\/?post_type=product&#038;p=2951"},"modified":"2026-08-22T13:02:10","modified_gmt":"2026-08-22T04:02:10","slug":"%ec%8b%9c%ed%97%98%ea%b8%b0-zw-300-%ec%8b%a4%ed%97%98%ec%8b%a4","status":"publish","type":"product","link":"https:\/\/gene-academy.com\/en\/product\/%ec%8b%9c%ed%97%98%ea%b8%b0-zw-300-%ec%8b%a4%ed%97%98%ec%8b%a4\/","title":{"rendered":"Limit tester 600ml industrial process microbial particles non-sterile membrane filter limit inspection equipment membrane filtration precision instrument laboratory industrial equipment"},"content":{"rendered":"<section>\n<h2>Product Information<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Product number<\/th>\n<td>1508805<\/td>\n<\/tr>\n<tr>\n<th>manufacturing company<\/th>\n<td>MSTJM<\/td>\n<\/tr>\n<tr>\n<th>Brand<\/th>\n<td>MSTJM<\/td>\n<\/tr>\n<tr>\n<th>model name<\/th>\n<td>ZW-300 Microbial Limit Tester (75kPa)<\/td>\n<\/tr>\n<tr>\n<th>Date of manufacture<\/th>\n<td>January 2026<\/td>\n<\/tr>\n<tr>\n<th>Product Location<\/th>\n<td>Overseas China<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section>\n<h2>Specifications<\/h2>\n<table>\n<tbody>\n<tr>\n<th>Rated power (kw)<\/th>\n<td>50W<\/td>\n<\/tr>\n<tr>\n<th>Machine size \/ W*D*H (mm)<\/th>\n<td>36\u00d718\u00d715cm<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/section>\n<section>\n<h2>Details<\/h2>\n<div id=\"editor_memo\">\n<div><span style=\"font-family: arial;font-size: 14pt\"><b>ZW-300 Microbial Limit Tester<\/b><\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 12pt\">&nbsp;1. Product Introduction<\/span><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;Inject the test sample into a microbial limit culture vessel. Filter the sample under negative pressure using the vacuum pump built into the test instrument and capture microorganisms on the filter membrane. Remove the filter membrane using a filter membrane remover and transfer the samples to a prepared solid culture medium with the bacterial surface facing upward. Cover the vessel to create a sealed culture box, and place it in a suitable incubator for incubation and counting.<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 12pt\">&nbsp;2. Technical parameters<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;<b>1. Power Supply: 220V\/50Hz<\/b><\/span><\/div>\n<div><b><br \/><\/b><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\"><b>&nbsp; &nbsp;2. Power: 50W<\/b><\/span><\/div>\n<div><b><br \/><\/b><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\"><b>&nbsp; &nbsp;3. Flow rate: \u2265600ml\/min<\/b><\/span><\/div>\n<div><b><br \/><\/b><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\"><b>&nbsp; &nbsp;4. Vacuum level: 75kPa<\/b><\/span><\/div>\n<div><b><br \/><\/b><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\"><b>&nbsp; &nbsp;5. Filter: Triple Filter<\/b><\/span><\/div>\n<div><b><br \/><\/b><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\"><b>&nbsp; &nbsp;6. Material: L304 Stainless Steel<\/b><\/span><\/div>\n<div><b><br \/><\/b><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\"><b>&nbsp; &nbsp;7. External dimensions: 36\u00d718\u00d715cm<\/b><\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 12pt\">3. Technical Characteristics<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;1. The integrated ultra-compact design reduces the space occupied by the laminar flow stage.<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;2. With its 2-in-1 functionality, it is not only the optimal choice for microbial limit testing, but it can also be used as a standalone vacuum pump, allowing for significant cost savings.<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;3. Three filter membranes can be filtered simultaneously, significantly improving work efficiency.<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;4. The filter cup is made of reusable material, making it durable, cost-effective, and easy to use.<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;5. Each filter head is controlled independently, allowing for flexible use by the operator.<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;6. Low noise due to the oil-free vacuum pump design.<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;7. The surface of the device is finished to be mirror-smooth to facilitate cleaning and disinfection.<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 12pt\">&nbsp;4. Application Areas<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;1. Pharmaceuticals: Purified water, water for injection, ophthalmic preparations, active medicinal ingredients, capsules, biological preparations, tablets, oral preparations<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;2. Food: Purified water, bottled water, beverages<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;3. Chemical Industry: Various water samples requiring microbiological testing<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;4. Cosmetics: Various water-based products<\/span><\/div>\n<div><\/div>\n<div><span style=\"font-family: arial;font-size: 10pt\">&nbsp; &nbsp;5. Disease Management: Rivers, Lakes, Seas, and Water Quality Samples<\/span><\/div>\n<\/div>\n<div class=\"water-marked\">\n\t<img decoding=\"async\" src=\"https:\/\/gene-academy.com\/wp-content\/uploads\/2026\/08\/zimg_1769126677_24.png\" alt=\" \uc6cc\ud130\ub9c8\ud06c \uc774\ubbf8\uc9c0\">\n\t<\/div>\n<div class=\"water-marked\">\n\t<img decoding=\"async\" src=\"https:\/\/gene-academy.com\/wp-content\/uploads\/2026\/08\/zimg_1769126689_8.jpg\" alt=\" \uc6cc\ud130\ub9c8\ud06c \uc774\ubbf8\uc9c0\">\n\t<\/div>\n<\/section>","protected":false},"excerpt":{"rendered":"<p>Precision filtration device with integrated vacuum pump for microbial limit testing, 600 ml\/min, # microbial limit test, # filter, #ZW-300, # precision testing equipment, # for laboratory use<\/p>","protected":false},"featured_media":2949,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[35],"product_tag":[],"class_list":["post-2951","product","type-product","status-publish","has-post-thumbnail","product_cat-35","first","instock","shipping-taxable","purchasable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/gene-academy.com\/en\/wp-json\/wp\/v2\/product\/2951","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/gene-academy.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/gene-academy.com\/en\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/gene-academy.com\/en\/wp-json\/wp\/v2\/comments?post=2951"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/gene-academy.com\/en\/wp-json\/wp\/v2\/media\/2949"}],"wp:attachment":[{"href":"https:\/\/gene-academy.com\/en\/wp-json\/wp\/v2\/media?parent=2951"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/gene-academy.com\/en\/wp-json\/wp\/v2\/product_brand?post=2951"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/gene-academy.com\/en\/wp-json\/wp\/v2\/product_cat?post=2951"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/gene-academy.com\/en\/wp-json\/wp\/v2\/product_tag?post=2951"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}